| SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4 F-DO, 24 V DC/ 2 A Can be parameterized via MSS ES 22.5 mm overall width Spring-type terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable |
| General technical data |
| Product brand name | | SIRIUS |
| Product category | | Modular Safety System |
| Product designation | | Expansion module |
| Design of the product | | 4 F-DO |
| Protection class IP | | IP20 |
| Shock resistance | | 15g / 11 ms |
| Degree of pollution | | 3 |
| Mounting position | | vertical |
| Installation altitude at height above sea level maximum | m | 2 000 |
| Ambient temperature | | |
| during storage | °C | -40 ... +85 |
| during operation | °C | -20 ... +60 |
| during transport | °C | -40 ... +85 |
| Relative humidity during operation | % | 10 ... 95 |
| Conducted interference due to burst acc. to IEC 61000-4-4 | | 2 kV (power ports) |
| Conducted interference due to conductor-earth surge acc. to IEC 61000-4-5 | | 2 kV |
| Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-5 | | 1 kV |
| Electrostatic discharge acc. to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
| Field-bound parasitic coupling acc. to IEC 61000-4-3 | | 10 V/m, 3 V/m, 1 V/m |
| Surge voltage resistance rated value | V | 500 |
| Insulation voltage rated value | V | 50 |
| Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | | K |
| Reference code acc. to DIN EN 61346-2 | | K |
| Product function | | |
| EMERGENCY OFF function | | No |
| protective door monitoring | | No |
| evaluation: electro-sensitive protective equipment | | No |
| evaluation: selector switch | | No |
| Pressure-sensitive mat monitoring | | No |
| evaluation: two-hand operator panel | | No |
| evaluation: enabling switch | | No |
| monitored start-up | | No |
| Control circuit/ Control |
| Type of voltage | | DC |
| Control supply voltage 1 at DC rated value | V | 24 |
| Operating range factor control supply voltage rated value of magnet coil | | 0.85 ... 1.15 |
| Auxiliary circuit |
| Product function | | |
| Parameterizable outputs | | Yes |
| Number of inputs | | |
| safety-related | | 0 |
| non-safety-related | | 0 |
| Number of outputs | | |
| as contact-affected switching element safety-related | | |
| — 1-channel | | 0 |
| — 2-channel | | 0 |
| as contact-less semiconductor switching element | | |
| — safety-related 2-channel | | 4 |
| — non-safety-related 2-channel | | 0 |
| for testing contact-based sensors | | 0 |
| Switching capacity current of semiconductor outputs at DC-13 at 24 V | A | 2 |
| Installation/ mounting/ dimensions |
| Mounting type | | standard rail |
| Width | mm | 22.5 |
| Height | mm | 105 |
| Depth | mm | 124 |
| Connections/Terminals |
| Product function removable terminal for auxiliary and control circuit | | Yes |
| Type of electrical connection for auxiliary and control current circuit | | spring-loaded terminals |
| Connectable conductor cross-section for auxiliary contacts | | |
| single or multi-stranded | mm² | 0.25 ... 1.5 |
| finely stranded | | |
| — with core end processing | mm² | 0.25 ... 1.5 |
| — without core end processing | mm² | 0.25 ... 1.5 |