| SIRIUS safety relay Basic unit Advanced series 3 electronic enabling circuits 1 electronic signaling circuit Us = 24 V DC Spring-type terminal (push-in) |
General technical data |
Product brand name | SIRIUS |
Product category | Safety relays |
Product designation | safety relays |
Design of the product | Solid-state enabling circuits |
Protection class IP of the enclosure | IP20 |
Protection against electrical shock | finger-safe |
Insulation voltage rated value | 50 V |
Ambient temperature | |
during storage | -40 ... +80 °C |
during operation | -25 ... +60 °C |
Air pressure acc. to SN 31205 | 90 kPa ... 106 kPa |
Relative humidity during operation | 10 ... 95 % |
Installation altitude at height above sea level maximum | 2 000 m |
Vibration resistance acc. to IEC 60068-2-6 | 5 ... 500 Hz: 0.75 mm |
Shock resistance | 10g / 11 ms |
Surge voltage resistance rated value | 800 V |
EMC emitted interference | IEC 60947-5-1, Class A |
Installation environment regarding EMC | This product is suitable for Class A environments only. It can cause undesired radio-frequency interference in residential environments. If this is the case, the user must take appropriate measures. |
Overvoltage category | 3 |
Degree of pollution | 3 |
Number of sensor inputs 1-channel or 2-channel | 1 |
Design of the cascading | yes |
Type of the safety-related wiring of the inputs | single-channel and two-channel |
Product feature cross-circuit-proof | Yes |
Safety Integrity Level (SIL) | |
acc. to IEC 61508 | 3 |
Performance level (PL) | |
acc. to EN ISO 13849-1 | e |
Category acc. to EN ISO 13849-1 | 4 |
Safe failure fraction (SFF) | 99 % |
PFHD with high demand rate acc. to EN 62061 | 0.0000000013 1/h |
PFDavg with low demand rate acc. to IEC 61508 | 0.000007 |
T1 value for proof test interval or service life acc. to IEC 61508 | 20 y |
Hardware fault tolerance acc. to IEC 61508 | 1 |
Safety device type acc. to IEC 61508-2 | Type B |
Number of outputs as contact-affected switching element | |
as NC contact | |
— for signaling function instantaneous contact | 0 |
— for signaling function delayed switching | 0 |
— safety-related instantaneous contact | 0 |
— safety-related delayed switching | 0 |
as NO contact | |
— for signaling function instantaneous contact | 0 |
— for signaling function delayed switching | 0 |
— safety-related instantaneous contact | 0 |
— safety-related delayed switching | 0 |
Number of outputs as contact-less semiconductor switching element | |
safety-related | |
— delayed switching | 0 |
— instantaneous contact | 3 |
for signaling function instantaneous contact | 1 |
Stop category acc. to DIN EN 60204-1 | 0 |
General technical data |
Design of input | |
cascading input/functional switching | Yes |
feedback input | Yes |
Start input | Yes |
Type of electrical connection Plug-in socket | No |
Operating frequency maximum | 2 000 1/h |
Switching capacity current | |
of semiconductor outputs at DC-13 at 24 V | 2 A |
Design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required | not required |
Wire length | |
with Cu 1.5 mm² and 150 nF/km per sensor circuit maximum | 4 000 m |
Make time with automatic start | |
at DC maximum | 85 ms |
Make time with automatic start after power failure | |
typical | 6 500 ms |
maximum | 6 500 ms |
Make time with monitored start | |
maximum | 85 ms |
Backslide delay time after opening of the safety circuits typical | 40 ms |
Backslide delay time in the event of power failure | |
typical | 0 ms |
maximum | 0 ms |
Recovery time after opening of the safety circuits typical | 30 ms |
Recovery time after power failure typical | 6.5 s |
Pulse duration | |
of the sensor input minimum | 60 ms |
of the ON pushbutton input minimum | 0.15 s |
Control circuit/ Control |
Type of voltage of the control supply voltage | DC |
Control supply voltage | |
at DC | |
— rated value | 24 V |
Operating range factor control supply voltage rated value of magnet coil | |
at DC | 0.8 ... 1.2 |
Power loss [W] typical | 2 W |
Installation/ mounting/ dimensions |
Mounting position | any |
Required spacing for grounded parts at the side | 5 mm |
Required spacing with side-by-side mounting at the side | 0 mm |
Mounting type | screw and snap-on mounting |
Width | 22.5 mm |
Height | 100 mm |
Depth | 121.6 mm |
Connections/Terminals |
Type of electrical connection | Push-in terminal |
Type of connectable conductor cross-sections | |
solid | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) |
finely stranded | |
— with core end processing | 1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²) |
— without core end processing | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²) |
Type of connectable conductor cross-sections at AWG conductors | |
solid | 1x (20 ... 16), 2x (20 ... 16) |
stranded | 1x (20 ... 16), 2x (20 ... 16) |
Product Function |
Product function parameterizable | Sensor floating / sensor non-floating, monitored start / autostart, 1-channel / 2-channel sensor connection, cross-circuit detection, startup testing, antivalent sensors, 2-hand switches |
Suitability for operation Device connector 3ZY12 | Yes |
Suitability for interaction press control | Yes |
Suitability for use | |
safety switch | Yes |
Monitoring of floating sensors | Yes |
Monitoring of non-floating sensors | Yes |
magnetically operated switch monitoring | Yes |
safety-related circuits | Yes |