3WT8165-0AA03-0AA0
WITHDRAWABLE NON-AUT. CIRCUIT-B.

From SIEMENS

WITHDRAW. NON-AUT. CIRCUIT-B. 4-POLE, SIZE I IN=1600A TO 500V, AC50/60HZ ICU=66KA AT 500V ONLY MOD-CENTER
Model
product brandnameSENTRON
Product designation3WT air circuit breaker
Design of the productIEC 60947-2
Type of the driving mechanismManual operating mechanism with stored energy feature, with mechanical closing
Type of the driving mechanism / motor driveNo
Design of the overcurrent releaseWithout, version old
General technical data
Number of poles4
Field of applicationNON-AUTOMATIC CIRCUIT-BREAKER
Size of the circuit-breakerI
Electrical endurance (switching cycles) / typical10 000
Usage categoryA
circuit-breaker / Design3WT8
Mechanical service life (switching cycles) / typical16 000
Equipment marking / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750Q
Voltage
Rated operational voltage Ue / max.500 V
Rated insulation voltage Ui1 000 V
Insulation voltage / at AC / rated value1 000 V
Surge voltage resistance / rated value12 kV
Protection class
Protection class IPIP20
Dissipation
Power loss [W]
maximum140 W
Electricity
rated current In
max.1 600 A
at 40 Cel1 600 A
at 50 Cel1 600 A
Continuous current / rated value1 600 A
Derating temperature / for the rated value of the continuous current50 °C
Short-time current resistance (Icw)
limited to 0.5 s / rated value50 kA
limited to 1 s / rated value50 kA
limited to 2 s / rated value30 kA
limited to 3 s / rated value25 kA
Main circuit
Operating frequency / 1 / rated value50 Hz
Operating voltage
for main current circuit / at AC / at 50 Hz / maximum500 V
for main current circuit / at AC / at 60 Hz / maximum500 V
Operating current
at 40 °C / rated value1 600 A
at 50 °C / rated value1 600 A
at 60 °C / rated value1 500 A
at 70 °C / rated value1 350 A
Auxiliary circuit
Operating current / of auxiliary contacts / at AC-15 / at 230 V6 A
Suitability
Suitability for use
Disconnecting meansYes
Product details
Product component
Trip indicatorNo
Auxiliary switchYes
Voltage triggerNo
undervoltage releaseNo
Product extension / optional / motor driveYes
Product function
Product function
Overload protectionNo
Accessories
accessoriesNo further Z accessories
Short circuit
Operational short-circuit current breaking capacity (Ics)
at 240 V / rated value66 kA
at 415 V / rated value66 kA
at 500 V / rated value66 kA
Maximum short-circuit current breaking capacity (Icu)
at 240 V / rated value66 kA
at 400 V / rated value66 kA
at 415 V / rated value66 kA
at 440 V / rated value66 kA
at 480 V / rated value66 kA
at 500 V / rated value66 kA
Connections
Arrangement of electrical connectors / for main current circuitLaminated contacts in guide frame
Type of connection, main circuitLAMINATED CONTACT IN GUIDE FRAME
Type of electrical connection / for main current circuitbusbar connection
Mechanical Design
Type of mountingWITHDRAWABLE UNIT
Mounting positionwith vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back
Mounting typedrawer unit
Environmental conditions
Ambient temperature
during operation / minimum-20 °C
during operation / maximum70 °C
during storage / minimum-40 °C
during storage / maximum80 °C

External links