4CH2100-1AA RING ROTARY TRANSFORMER;
From SIEMENS
| RING ROTARY TRANSFORMER; PHASES:1; PN(KVA):2,3; UPRI(V):230; USEC(V):0-230; ISEC(A):10; F(HZ):50...400; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:40 /E; IP00; MANUAL OPERATION; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; VDE 0552 | |||
| General technical data: | |||
| Product designation | |||
| Product brand name | SIDAC | ||
| Operating apparent output for harsh operating conditions rated value | V·A | 1.85 | |
| Operating apparent output rated value | kV·A | 2.3 | |
| Connection method for transformers | Ia0 | ||
| Certificate of suitability | CE | ||
| Product function Temperature monitoring | No | ||
| Inputs: | |||
| Phase number of the inputs | 1 | ||
| Input voltage _1 rated value | V | 230 | |
| Electrical input frequency | |||
| minimum | Hz | 50 | |
| maximum | Hz | 400 | |
| Outputs: | |||
| Phase number of the outputs | 1 | ||
| Output voltage | |||
| maximum | V | 230 | |
| minimum | V | 0 | |
| Output current | |||
| maximum | A | 10 | |
| minimum | A | 0 | |
| for harsh operating conditions maximum | A | 8 | |
| Electrical output frequency | |||
| maximum | Hz | 400 | |
| minimum | Hz | 50 | |
| Ambient conditions: | |||
| Thermal class acc. to IEC 60085 | E | ||
| Ambient temperature rated value | °C | 40 | |
| Protection class IP | IP00 | ||
| Mechanical data: | |||
| Type of electrical connection | |||
| at input for main current circuit | screw-type terminals | ||
| at output for main current circuit | screw-type terminals | ||
| Design of the Actuating drive version | manual operation | ||
| Mounting type | screws | ||
| Width | m | 0.175 | |
| Height | m | 0.16 | |
| Depth | m | 0.145 | |